QUESTION

Is it possible to create user-specific device databases for µVision?

ANSWER

Yes. The names of additional Device Databases must be manually added to the C:\KEIL\TOOLS.INI file. For example, you may want to create a device database that contains all of the Philips SmartCards. To do so, in TOOLS.INI, under the section [UV2], create a CDBx setting as shown below.

[UV2]
CDB0=UV2\PCARDS.CDB("Philips Smart Cards")

This allows you to access a Device Database file (with the name PCARDS.CDB) stored in the C:\KEIL\UV2 folder.